No matter where you read the current fault code (indoor, outdoor or wall control) the fault code will always be the same?
Some fault codes may be indicated by flashing LED’s on the indoor or outdoor boards?
To properly charge a unit you must know the __________.
The 601, 701 and 801 controls are
A 24 volt interface is used _______________
A wireless control is used for __________________
The new service codes are _______________
The second digit of the Error code shows ____________
A function code will
The most common fault on start up is ________________
Standard wiring between the indoor and the outdoor is ________.
If there is high electromagnetic interference (EMF) causing communication issues you should
If you need to splice the communication wires you may
Communication is carried on which wires?
An external drain safety should break?
Communication voltage is?
Induced current on the S (3) wire is due to?
Which indoor units have a display board?
Ductless outdoor units have
Static pressure can be set on the _____________
Anti cold air function is to _______________
As shipped from the factory, in cool mode the indoor fan in auto selection
All of the outdoor units have
On the 24 volt interface a code reading 20 means_______.
The term ductless system means
The Debugger tool can be used to ramp the compressor up and down when attached to the outdoor unit?
The debugger tool can be used to simulate the indoor or outdoor unit to verify communication faults?
The The Debugger tool connects to
With the Debugger tool do you need an indoor unit connected to operate the outdoor unit?
Induced voltage on the S wire as low as 6 volts can interfere with communication.
The most frustrating codes to diagnose are
The speed of the compressor is controlled by
Multi-head ductless ________________
Using the wireless remote in the service menu you can program the blower from running continuously during the off cycle in cool mode
With the ducted unit it is preferred to set static pressure by
Using the System Enquiry function from the Multi-zone outdoor unit you can tell if you have your communication wiring matched to the correct piping?
On a 1-1 indoor coil freeze up fault is the same as refrigerant leak detection?
On a multi-zone any unit not calling will close its EEV
When the unit is in protection mode, the unit will ___________.
Compressor discharge protection starts at
High compressor discharge temperature is most likely caused by
The condenser fan speed is controlled by the
If the compressor temperature is between 215 and 229 degrees the compressor will
Where would you install a liquid line filter drier in a ductless system?
The Check Point function on a multi-head
On a multi-head outdoor unit the display normally
When using the check point function you can see
When using the check point function you can see
Using the check point function what would be the most useful point to check?
When using the Debugger Tool you