Technical info can be found where?
When wiring a system, you need to
How should a condensate float switch be wired in?
Place these in the correct order of sequence
View Answers:
What benefits do we get from using nitrogen during a refrigeration repair?
You should pressure test a system with nitrogen above the systems normal operating pressures?
To get into the setup menu of the indoor units you need to?
On ducted indoor units you need to setup your static pressure by using dip switches or the controller?
All indoor units need to be in the same mode of operation to work correctly?
When on a service call you should?
When checking fault codes, the indoor unit and outdoor unit will show the same error code designation all the time?
When troubleshooting a communication code, you should
A E1 code only means a loss of communication?
When checking the Communication L2 -S, the DC voltage should be_________ when working correctly?
When checking a thermistor, you should?
When ohming a compressor the compressor should have __________________ windings?
Do ductless systems need cleaning?
Ductless systems achieve a SEER up to?
A ductless outdoor must be connected to a ductless indoor only?
You can connect a ductless outdoor to a gas furnace and standard evaporator coil.
A proper heat load is?
System size is determined by?
The 38MARB series maintain 100% heat capacity to?
Ductless system meter refrigerant at the___________?
Ductless systems operate in?
Heating compensation is used to calibrate return sensor to___________.
No matter where you read the current fault code (indoor, outdoor or wall control) the fault code will always be the same?
The most common fault on start up is ________________
Standard wiring between the indoor and the outdoor is ________.
If there is high electromagnetic interference (EMF) causing communication issues you should
If you need to splice the communication wires you may
Communication is carried on which wires?
An external drain safety should break?
Communication voltage is?
Induced current on the S (3) wire is due to?
Which indoor units have a display board?
Ductless outdoor units have
Some fault codes may be indicated by flashing LED’s on the indoor or outdoor boards?
Static pressure can be set on the _____________
Anti cold air function is to _______________
As shipped from the factory, in cool mode the indoor fan in auto selection
All of the outdoor units have
On the 24 volt interface a code reading 20 means_______.
The term ductless system means
The Debugger tool can be used to ramp the compressor up and down when attached to the outdoor unit?
The debugger tool can be used to simulate the indoor or outdoor unit to verify communication faults?
The The Debugger tool connects to
With the Debugger tool do you need an indoor unit connected to operate the outdoor unit?
To properly charge a unit you must know the __________.
Will I practice what I have learned today? And do my best to represent my industry as a professional?